Operation CHARM: Car repair manuals for everyone.

Programming and Relearning








SLIDING ROOF: SLIDING ROOF SYSTEM: INITIALIZATION

INITIALIZATION

1. INITIALIZATION PROCEDURE
NOTICE:
- When replacing the sliding roof drive gear, the new sliding roof drive gear requires initialization. If a reset is not executed, the following functions do not operate: AUTO operation, the jam protection function and key-off operation.
- During initialization, do not apply a physical shock, such as opening/closing a door or driving the vehicle at 5 km/h (3.10 mph) or more, to the vehicle and do not perform the following electrical operations:
(1) Cranking the engine
(2) Turning the ignition switch from ON to off
(3) Operating the power window switches
(4) Operating the window defogger switch
(5) Operating the blower switch
(6) Locking/Unlocking the door
(7) Operating the headlight dimmer switch
HINT: When the cable is disconnected and reconnected to the negative (-) battery terminal or the drive gear connector is disconnected and reconnected, the sliding roof drive gear (pulse sensor initial position setting) initialization is not necessary.

(a) Turn the ignition switch to ON.
(b) Make sure that the sliding roof is fully closed.
(c) ->->->->->Push and hold the TILT UP switch until the following movement finishes: tilt up approximately 1 second pause tilt down slide open approximately 1 second pause slide closed.
NOTE: Make sure not to release the switch during the initialization. If the switch is released, perform the initialization again.

(d) Check that the sliding roof stops at the fully closed position.
(e) The initialization is complete.
(f) Check that the AUTO operation works normally.
HINT:
- If the sliding roof cannot be fully closed or its position has become misaligned, perform initialization again.
- If initialization fails or the roof position is misaligned, the initialization cancel procedure must be performed.

2. INITIALIZATION CANCEL PROCEDURE
HINT: If initialization fails or the roof position is misaligned, the initialization cancel procedure must be performed.

(a) Make sure that the sliding roof is in the full tilt up position.
(b) Hold the TILT UP switch for 10 seconds or more.
(c) The initialization cancel is complete.