Refrigerant: Testing and Inspection
AIR CONDITIONING: REFRIGERANT: ON-VEHICLE INSPECTION
1. CHECK REFRIGERANT PRESSURE USING MANIFOLD GAUGE SET
(a) This is a method to identify trouble areas by using a manifold gauge set. Read the manifold gauge pressure under the following conditions.
Test conditions:
* Engine warm.
* All doors fully open.
* A/C switch ON.
* Blower speed control switch at HI.
* Engine running at 1,500 rpm.
* Air inlet mode damper set at recirculation.
* Temperature control lever in MAX. COLD position.
* Air temperature at air inlet 30 to 35°C (86 to 95°F).
(1) When the refrigerant volume is correct, the gauge reading indicates as follows:
Gauge reading:
HINT
Pressure varies in accordance with certain conditions (outside air temperature, sunlight and wind).
(2) When there is moisture in the refrigeration system:
(3) When cooling is insufficient:
(4) When the circulation of the refrigerant is poor:
(5) When the refrigerant does not circulate:
(6) When the refrigerant is overcharged or cooling of condenser is insufficient:
(7) When there is air in the refrigeration system:
(8) When the expansion valve malfunctions:
When the compressor is defective:
2. INSPECT IDLING SPEED
(a) Warm up the engine.
(b) Inspect the idling speed when these conditions are established.
* Engine warm
* When checking the idling speed, shift the transmission to either the neutral position or the parking position.
Standard:
for manual transaxle
for automatic transaxle
If the idling speed is not as specified, check the idle control system.