Blower Motor: Service and Repair
Blower MotorFig. 9 Exploded view of blower motor & housing. 1984:
1. Disconnect battery ground cable.
2. Remove blower cover and package tray, Fig. 9.
3. Remove glove box.
4. Remove large duct between heater and blower assemblies.
Fig. 10 Blower motor retaining bolts location. 1984:
5. Set actuator lever to CIRC position and disconnect vacuum hose from servo. If lever is not set to CIRC position, it will be difficult to remove vacuum hose.
6. Unplug blower motor electrical connections.
7. Remove servo retaining screws and clip.
8. Remove servo from blower assembly.
9. Remove blower retaining nuts and bolts and blower, Fig. 10.
10. Reverse procedure to install.