Positive Crankcase Ventilation: Service and Repair
Throttle Chamber:
REMOVAL
1. Remove the hose from the valve.
2. Remove the valve in the CCW direction.
INSTALLATION
1. Reinstall the valve and tighten to 14 - 19 ft lb (20 - 35 Nm).
2. Reconnect the hose.