Disassembly and Reassembly
Distributor:
DIstributor Cap And Rotor:
DISASSEMBLY
1. Remove the distributor cap and rotor.
2. Remove the dust cover and seal ring.
Ground Harness:
3. Disconnect the ground harness.
Pulse Generator Screws:
4. Remove the screws securing the sensor assembly to the distributor housing.
Top View Of Distributor:
ASSEMBLY
1. Assemble in reverse order.
Air Gap:
2. Adjust reluctor air gap as follows:
a. Using a brass feeler gauge, measure the distance between the reluctor tips and each pole.
b. Move reluctor until all gaps are equal.
AIR GAP CLEARANCE
0.008 - 0.016 in (0.2 - 0.4 mm)