DTC 36
DIAGNOSIS:
- The air suction solenoid valve is not in function.
- The harness connector between ECM and air suction solenoid valve is in short or open.
1. CHECK INPUT SIGNAL FOR ECM.
1. Turn ignition switch to ON.
2. Measure signal voltage between ECM and body.
Connector & terminal / Specified voltage:
(E31) No.3 - Body / 10 V, max.
2. CHECK AIR SUCTION SOLENOID VALVE.
1. Turn ignition switch to OFF.
2. Disconnect connector from air suction solenoid valve.
3. Measure resistance between connector Terminals of air suction solenoid valve.
Terminals / Specified resistance:
No.1 - No.2 / 36 Ohm at 20 °C (68 °F)
3. CHECK POWER SUPPLY TO AIR SUCTION SOLENOID VALVE.
1. Turn ignition switch to ON.
2. Measure voltage between air suction solenoid valve connector and body.
Connector & terminal / Specified voltage:
(E3) No.1 - Body / 10 V, max.