Lateral Accelerometer: Testing and Inspection
1. Disconnect sensor connector and measure contact resistance between terminals as follows:a. With sensor on flat surface, resistance should be 550-670 ohms.
b. Sensor should turn Off from On (610 ohms to more than 100,000 ohms) when it is tilted in a range from 14°-21.3°.