Refrigerant Oil: Service and Repair
Lubrication1. SYSTEM OIL STABILIZATION
Prior to opening the refrigerant system for repairs (except compressor seizure) the system must be stabilized for correct oil replenishment.
Follow these procedures:
1. Engine speed set to 1,500 rpm
2. A/C "ON"
3. Air source to recirculate
4. Blower in 4th or high speed position
- Make sure the air entering the evaporator is above 26.7 °C (80 °F).
- The discharge (high) side pressure must be above 588 kPa (6 kg/sq.cm, 85 psi).
5. Operate the A/C for 10 minutes.
2. SYSTEM DISCHARGE
Slowly, discharge the system starting with the high-pressure side until the pressure drops below 345 kPa (3.52 kg/sq.cm, 50 psi), then open the low-pressure side.
3. OIL REPLACEMENT
After stabilization and discharge, replace the component, adding the appropriate amount of oil (ZXL100PG/ZXL200PG) to the new component before installation.
If the compressor is replaced (after stabilization):
1. Drain and measure the oil from the original compressor.
2. Drain the oil from the replacement compressor and refill with the same amount that was drained from the original [20 ml (0.7 US fl oz, 0.7 Imp fl oz) minimum]. Always use ZXL100PG for the replacement oil.