Removal and Installation
REMOVAL AND INSTALLATION1. Disconnect the positive (+) terminal after disconnecting the negative (- ) terminal of battery.
2. Remove flange nuts from battery rods and take off battery holder.
3. Remove battery.
4. Installation is in the reverse order of removal.
Tightening torque:
3.4 ± 1.0 N.m (0.35 ± 0.1 kg-m, 25 ± 0.7 ft-lb)
NOTE:
- Clean battery cable terminals and apply grease to retard the formation of corrosion.
- Connect the positive (+) terminal of battery and then the negative (- ) terminal of the battery.