Operation CHARM: Car repair manuals for everyone.

Test 10AC12





TEST 10AC12: CHECK BATTERY SHORT OF SOLENOID VALVE
1) Disconnect connector (ABS1, F9) from hydraulic unit.
2) Turn ignition switch to ON.
3) Measure voltage between hydraulic unit connector and chassis ground.
Connector & terminal: (F9) No. 4 (+) & Chassis ground (-)
CHECK: Is voltage 0 Volt?
YES: Test 10AC13