Operation CHARM: Car repair manuals for everyone.

ABS Only

CLEARING MEMORY





1. After calling up a trouble code, disconnect ABS diagnosis connector terminal 6 from diagnosis terminal.
2. Repeat 3 times within approximately 12 seconds; connecting and disconnecting terminal 6 and diagnosis terminal for at least 0.05 seconds each time.





NOTE: After diagnosis is completed, always clear memory. Make sure only start code (11) is shown after memory is cleared.