Test 8W2
TEST 8W2: CHECK VALVE RELAY CONTACT POINT
1) Connect battery to valve relay terminals No. 85 and No. 86.
2) Measure resistance between valve relay terminals.
Terminals: No. 30 & No. 87
CHECK: Is the resistance less than 0.5 ohms?
YES: Test 8W3
NO: Replace valve relay.