Barometric Pressure Sensor: Service and Repair
PRESSURE SENSORA: REMOVAL AND INSTALLATION
1) Disconnect battery ground cable.
2) Disconnect connector from pressure sensor.
3) Disconnect hose from pressure sensor.
4) Remove pressure sensor from bracket.
5) Installation is in the reverse order of removal.
Tightening torque: 6.4 ± 0.5 N.m (0.65 ± 0.05 kg-m, 4.7 ± 0.4 ft-lb)