Oil Pressure Sender: Service and Repair
A: REMOVAL1. Remove alternator from bracket.
1. Disconnect connector and terminal from generator.
2. Remove V-belt cover.
3. Loosen lock bolt and slider bolt, and remove front side V-belt.
4. Remove bolts which install generator on bracket.
2. Disconnect terminal from oil pressure switch.
3. Remove oil pressure switch.
B: INSTALLATION
1. Apply fluid packing to oil pressure switch threads before installation.
Fluid packing: THREE BOND 1215 or equivalent
2. Install oil pressure switch onto engine block. As
Tightening torque: 25 ± 3 Nm (2.5 ± 0.3 kg-m, 18. 1 ± 2.2 ft. lbs.)
3. Connect terminal of oil pressure switch.
4. Install generator on bracket and temporary tighten installing bolts.
5. Install front side V-belt and adjust it.
6. Install V-belt cover.
7. Connect connector and terminal to generator.