Neutral Safety Switch: Adjustments
B: ADJUSTMENT1) Loosen the three inhibitor switch securing bolts.
2) Shift the select lever to the N range.
3) Insert ST as vertical as possible into the holes in the inhibitor switch lever and switch body.
ST 499267300 STOPPER PIN
4) Tighten the three inhibitor switch bolts.
Tightening torque: 3.4±0.5 Nm (0.35±0.05 kg-m, 2.5±0.4 ft. lbs.)