Discharge System
CAUTION: The following points must be kept in mind when discharging the system.- Be certain that goggles and gloves are worn.
- Connect refrigerant recovery system to manifold gauge set and remove recycle refrigerant from the A/C system.
NOTE: Refer to that refrigerant recovery system instruction manual for operating procedures.
A: CONNECTING THE MANIFOLD GAUGE SET
1. Close the high and low side manifold valves.
2. Turn the A/C system ON and turn the IG switch OFF.
3. Attach the high- and low-pressure manifolds to the high and low services port on the vehicle.
B: PREPARE FOR DISCHARGING
Connect center manifold hose to refrigerant recovery system to recycle refrigerant.