Power and Ground Distribution: Testing and Inspection
2E1: CHECK BATTERY.Measure battery specific gravity of electrolyte.
CHECK : Is battery specific gravity more than 1.250?
YES : Go to step 2E2.
NO : Charge or replace battery. Go to step 2E2.
2E2: CHECK FUSES, CONNECTORS AND HARNESSES.
Check the condition of the main and other fuses, and harnesses and connectors. Also check for proper grounding.
CHECK : Is there anything unusual about the appearance of main fuse, fuse, harness, connector and grounding?
YES : Repair or replace faulty parts. End of pre-inspection.