Keyless Entry: Service and Repair
KEYLESS ENTRY CONTROL MODULE1. Disconnect battery ground cable.
2. Remove lower cover and then disconnect connector.
3. Remove keyless entry control module (A) while disconnecting connector.
4. Installation is in the reverse order of removal.
Tightening torque: 7.4 ± 2.5 Nm (0.75 ± 0.25 kg.m, 5.4 ± 1.8 ft.lb)