Installation
Installation is in the reverse order of removal.Do the following:1. Always use new gaskets.
2. Ensure sealing portion is free from fuel or foreign particles before installation.
3. Tighten nuts in numerical sequence shown in Figure to specified torque.
Tightening torque:
4.4 ± 1.5 N.m (0.45 ± 0.15 kg.m, 33 ± 1.1 ft.lb)
4. Connect connector to fuel pump relay.