Dropping Resistor
24. Dropping ResistorA: REMOVAL AND INSTALLATION
1. Disconnect battery ground terminal.
2. Remove air intake duct.
3. Disconnect connector from dropping resistor.
4. Remove dropping resistor from bracket
5. Install dropping resistor.
Tightening torque: 6.4 ± 0.5 Nm (0.65 ± 0.05 kg-m, 4.7 ± 0.4 ft. lbs.)