Diagnostics Item 5 (6F)
6F1: CHECK HARNESS CONNECTOR BETWEEN SECURITY CONTROL MODULE AND COMBINATION METER.1. Disconnect connector from security control module and combination meter.
Connector & Terminal - [(B93) No.5 - (i10) No.23]:
2. Measure resistance between security control module connector (B93) and combination meter connector (i10).
CHECK: Is the resistance less than 10 Ohms?
YES: Go to step 6F2.
NO: Repair wiring harness between security control module and combination meter.
6F2: CHECK HARNESS CONNECTOR BETWEEN FRONT DOOR SWITCH RH AND COMBINATION METER.
1. Disconnect connector from front door switch RH.
Connector & Terminal - [(R12) No.1 - (i10) No.28]:
2. Measure resistance between front door switch RH connector (R12. and combination meter connector (i10).
CHECK: Is the resistance less than 10 Ohms?
YES: Go to step 6F3.
NO: Repair wiring harness between front door switch RH and combination meter.
6F3: CHECK COMBINATION METER CIRCUIT.
1. Remove combination meter.
Terminals [No.28 - No.23]:
2. Measure resistance between combination meter terminals.
CHECK: Is the resistance less than 10 Ohms?
YES: Replace security control module.
NO: Repair or replace combination meter.