Subaru Select Monitor - Actuator Operation
Subaru Select Monitor - Actuator Operation
Preparation Tool:
1. Prepare Subaru Select Monitor kit.
2. Connect diagnosis cable to Subaru Select Monitor.
3. Insert cartridge into Subaru Select Monitor.
4. Connect test mode connector (A) at the lower portion of instrument panel (on the driver's side).
5. Connect Subaru Select Monitor to data link connector.
a. Connect Subaru Select Monitor to data link connector (A) located in the lower portion of the instrument panel (on the driver's side).
b. Connect diagnosis cable to data link connector.
CAUTION: Do not connect scan tools except for Subaru Select Monitor and OBD-II general scan tool.
6. Turn ignition switch to ON (engine OFF) and Subaru Select Monitor switch to ON.
7. On the
8. On the
9. Press the [YES] key after displayed the information of engine type.
10. On the
11. On the
12. Select the desired compulsory actuator on the
13. Pressing the [NO] key completes the compulsory operation check mode. The display will then return to the
A list of the support data is shown in the table.
NOTE: The following parts will be displayed but not functional because they are not installed on the vehicle.
Display
EGR Solenoid Valve
ASV Solenoid Valve
FICD Solenoid
Pressure Switching Sol. 1
Pressure Switching Sol. 2
For detailed operation procedure, refer to the SUBARU SELECT MONITOR OPERATION MANUAL.