With Manufacturer's Scan Tool
SUBARU SELECT MONITOR (NORMAL MODE)1. On the �Main Menu� display screen, select the {2. Each System Check} and press the [YES] key.
2. On the �System Selection Menu� display screen, select the {Engine Control System} and press the [YES] key.
3. Press the [YES] key after displayed the information of engine type.
4. On the �Engine Diagnosis� display screen, select the {Clear Memory} and press the [YES] key.
5. When the "Done" and "Turn Ignition Switch OFF" are shown on the display screen, turn the Subaru Select Monitor and ignition switch to OFF.
NOTE:
- After the memory has been cleared, the idle air control solenoid valve must be initialized. To do this, turn the ignition switch to the ON position. Wait 3 seconds before starting the engine.
- For detailed operation procedure, refer to the SUBARU SELECT MONITOR OPERATION MANUAL.
SUBARU SELECT MONITOR (OBD MODE)
1. On the �Main Menu� display screen, select the {2. Each System Check} and press the [YES] key.
2. On the �System Selection Menu� display screen, select the {Engine Control System} and press the [YES] key.
3. Press the [YES] key after displayed the information of engine type.
4. On the �Engine Diagnosis� display screen, select the {OBD System} and press the [YES] key.
5. On the �OBD Menu� display screen, select the {4. Diagnosis Code(s) Cleared} and press the [YES] key.
6. When the "Clear Diagnostic Code?" is shown on the display screen, press the [YES] key.
7. Turn the Subaru Select Monitor and ignition switch to OFF.
NOTE:
- After the memory has been cleared, the idle air control solenoid valve must be initialized. To do this, turn the ignition switch to the ON position. Wait 3 seconds before starting the engine.
- For detailed operation procedure, refer to the SUBARU SELECT MONITOR OPERATION MANUAL.