Automatic Air Conditioning
Automatic Air Conditioning
SWITCH FUNCTIONS
NOTE: The beeper for button operation confirmation has been discontinued.
1. AUTOMATIC CONTROL OPERATION
- AUTO switch: When this switch is pressed (ON), the air outlet selection, blower fan speed, air temperature, fresh/recirculation switching, and compressor operation are automatically controlled. When the AUTO switch is pressed second time, the compressor operates in the ECON mode. In the ECON mode, the ECM controls compressor operation based on inputs from the intake air temperature sensor. Compressor operating time in the ECON mode is shorter than in the AUTO mode.
- Temperature set switch: A desired cabin temperature can be set in 0.5 °C increments.
- OFF/Bright switch: When this switch is pressed, the blower fan and compressor stop and all the indicators go out.
Setting the light switch to the "OFF" or "Bright" position causes the illuminating icons on the display panel to dim. When traveling with the lights on in gloomy daylight or in twilight, press the OFF switch for 1 second or longer if you feel it is too hard to identify the icons clearly. The brightness comes back to normal.
2. MANUAL CONTROL OPERATION
- A/C switch: The air-conditioner turns on when this switch is pressed first and turns off when it is pressed second time.
- Blower fan switch: Fan speed changes in the order of Lo, M1, M2 and Hi, every time it is pressed.
- Ambient temperature display switch: When this switch is pressed momentarily, the ambient temperature is indicated on the display for 5 seconds. When this switch is depressed for more than 1 seconds, the ambient temperature is continuously indicated.
- Defroster switch: When this switch is pressed, air flow is directed toward the windshield and side widows for defrosting, outside air is drawn into the passenger compartment, and the A/C compressor is engaged.
- Rear defogger switch: Pressing this switch causes the rear defogger to operate for 15 minutes.
- Fresh/Recirc switch: Every time this switch is pressed, switching takes place between outside air introduction and inside air recirculation alternately.
- Mode selector switch: Pressing this switch changes the outlets to which the air is directed in the order shown.