Actuator Operation
Compulsory Valve Operation Check ModeOPERATION
1. Prepare the Subaru Select Monitor kit.
2. Connect the diagnosis cable to Subaru Select Monitor.
3. Insert the cartridge into Subaru Select Monitor.
4. Connect the test mode connector (A) at the lower portion of the instrument panel (on the driver's side).
5. Connect the Subaru Select Monitor to data link connector.
1. Connect the Subaru Select Monitor to data link connector located at the lower portion of the instrument panel (on the driver's side).
2. Connect the diagnosis cable to data link connector.
CAUTION: Do not connect scan tools other than the Subaru Select Monitor or OBD-II general scan tools.
6. Turn the ignition switch to ON (engine OFF) and Subaru Select Monitor switch to ON.
7. On the [[Main Menu]] display screen, select {2. Each System Check} and press the [YES] key.
8. On the [[System Selection Menu]] display screen, select {Engine Control System} and press the [YES] key.
9. Press the [YES] key after the engine type information is displayed.
10. On the [[Engine Diagnosis]] display screen, select {System Operation Check Mode} and press the [YES] key.
11. On the [[System Operation Check Mode]] display screen, select {Actuator ON/OFF Operation} and press the [YES] key.
12. Select the desired compulsory actuator on the <,Actuator ON/OFF Operation]] display screen and press the [YES] key.
13. Pressing the [NO] key completes the compulsory operation check mode. The display will then return to the [[Actuator ON/OFF Operation]] screen.
- A list of the support data is shown in the table.
NOTE:
- The following parts will be displayed but not functional because they are not installed on the vehicle.
Display
EGR Solenoid Valve
ASV Solenoid Valve
FICD Solenoid
Pressure Switching Sol. 1
Pressure Switching Sol. 2
AAI Solenoid Valve
- For detailed operation procedures, refer to the SUBARU SELECT MONITOR OPERATION MANUAL.