Variable Induction Control Actuator: Service and Repair
Tumble Generator Valve ActuatorREMOVAL
RH SIDE
1. Lower the fuel pressure.
2. Open the fuel filler lid and remove the fuel filler cap.
3. Disconnect the ground cable from battery.
4. Remove the intake manifold.
5. Disconnect the connector from tumble generator valve actuator RH.
6. Remove tumble generator valve RH.
LH SIDE
1. Lower the fuel pressure.
2. Open the fuel filler lid and remove the fuel filler cap.
3. Disconnect the ground cable from battery.
4. Disconnect the connector from tumble generator valve LH.
5. Remove tumble generator valve actuator LH.
INSTALLATION
RH SIDE
Install in the reverse order of removal.
LH SIDE
Install in the reverse order of removal.