EGR Valve: Service and Repair
REMOVAL1. Disconnect battery ground cable.
2. Disconnect connector from EGR valve.
3. Remove EGR valve from intake manifold.
INSTALLATION
Install in the reverse order of removal.
Tightening torque: 19 N.m (1.9 kgf-m, 14.0 ft-lb)