Removal and Installation
GeneratorREMOVAL
1. Disconnect the ground cable from battery.
2. Disconnect the connector and terminal from generator.
- NON-TURBO MODEL
- TURBO MODEL
3. Remove the V-belt cover.
4. Remove the front side V-belt.
5. Remove the bolts which install generator onto bracket.
INSTALLATION
Install in the reverse order of removal.
Tightening torque: 25 N.m (2.5 kgf.m, 18.1 ft.lb)
CAUTION: Check and adjust the V-belt tension.