Operation CHARM: Car repair manuals for everyone.

Variable Induction Control Valve: Service and Repair

REMOVAL

1. Release the fuel pressure.
2. Open the fuel filler lid and remove the fuel filler cap.




3. Disconnect the ground cable from battery.
4. Remove the throttle body.
5. Disconnect the connector from tumble generator valve actuator.




6. Remove the tumble generator valve actuator.

INSTALLATION
Install in the reverse order of removal.
Tightening torque: 5.9 N.m (0.60 kgf.m, 4.3 ft.lb)