Initial Inspection
INSPECTIONBefore performing diagnosis, check the following item which might affect the occupant detection system problems.
CAUTION:
- All the airbag system wiring harnesses and connectors are colored yellow. Do not use electrical test equipment on these circuits.
- Be careful not to damage the airbag system wiring harness or connectors when servicing the occupant detection system
1. BATTERY
Measure the battery voltage and specific gravity and check electrolyte.
Standard voltage:
12 V or more
Specific gravity:
Above 1.260
Electrolyte:
Between the upper level and lower level
2. AIRBAG SYSTEM
Read the DTC of airbag system, and check that there is no malfunction in airbag system.
Standard:
DTC is not displayed.