P2011
DTC P2011 INTAKE MANIFOLD RUNNER CONTROL CIRCUIT/OPEN (BANK 2)1. OUTLINE OF DIAGNOSIS
Detect the open or short circuit of tumble generator valve motor.
Judge NG when the open signal is sent from IC after tumble generator valve driving IC diagnosis.
2. COMPONENT DESCRIPTION
3. ENABLE CONDITION
4. GENERAL DRIVING CYCLE
Always perform the diagnosis continuously.
5. DIAGNOSTIC METHOD
Judge NG when the malfunction criteria are completed by tumble generator valve driving IC, and then NG signal is sent to main IC. At the main IC, check the sent signal at each timing which occurs just before the tumble generator valve output is set to ON and OFF, and judge open NG when the open NG signal is sent during 2 seconds in a row. Judge OK and clear the NG when the OK signal is sent.
6. DTC CLEAR CONDITION
- When the OK idling cycle was completed 40 times in a row
- When "Clear Memory" was performed
7. MALFUNCTION INDICATOR LIGHT CLEAR CONDITION
- When the OK driving cycle was completed 3 times in a row
- When "Clear Memory" was performed
8. FAIL SAFE
Tumble generator valve control: Not allowed to move tumble generator valve.
9. ECM OPERATION AT DTC SETTING
Memorize the freeze frame data. (For test mode $02)