Torque Specifications
Cylinder Head Bolts1. Tighten all bolts in alphabetical sequence 40 Nm (4.1 kgf-m, 29.5 ft. lbs.)
2. Retighten all bolts in alphabetical sequence 95 Nm (9.7 kgf-m, 70.1 ft. lbs.)
Caution: If the bolt make stick-slip sound during tightening, repeat the procedure from step (1). In this case, the cylinder head gasket can be reused.
3. Loosen all the bolts in reverse order of installation 180°
4. Loosen again in the same order 180°
5. Tighten all bolts in alphabetical sequence 10 Nm (1.0 kgf-m, 7.4 ft. lbs.)
6. Retighten all bolts in alphabetical sequence 30 Nm (3.1 kgf-m, 22.1 ft. lbs.)
7. Retighten all bolts in alphabetical sequence 60 Nm (6.1 kgf-m, 44.3 ft. lbs.)
8. Retighten all bolts in alphabetical sequence 80 - 90°
9. Retighten all bolts in alphabetical sequence 40 - 45°
Caution: The tightening angle of the bolt should not exceed 45°
10. Retighten bolts (a) and (b) by 40 - 45°
Caution: Make sure the total "tightening angle" of steps (9) and (10) does not exceed 90°.
Camshaft Bearing Cap Bolts
First pass: T1 9.75 N-m (1.0 kgf-m, 7.2 ft. lbs.)
Final pass: T2 20 N-m (2.0 kgf-m, 14.5 ft. lbs.)
Tightening torque:
LH Cylinder Block To RH Cylinder Block Bolts
For cylinder block tightening specifications and sequence, please refer to Overhaul. Service and Repair
Connecting Rod Cap Bolts 52 N-m (5.3 kgf-m, 38.4 ft. lbs.)
Crankshaft Pulley Bolt
For crankshaft pulley bolt tightening specifications and sequence, please refer to Overhaul. Service and Repair
Flywheel Bolts 72 N-m (7.3 kgf-m, 52.8 ft. lbs.)
Flex Plate Bolts 72 N-m (7.3 kgf-m, 52.8 ft. lbs.)
Oil Pump Bolts 6.4 N-m (0.65 kgf-m, 4.7 ft. lbs.)
Water Pump Bolts
First pass 12 N-m (1.2 kgf-m, 8.9 ft. lbs.)
Final pass 12 N-m (1.2 kgf-m, 8.9 ft. lbs.)