With VDC
VDC Sequence ControlOPERATION
1) While the VDC sequence control is performed, the operation of the hydraulic unit can be checked using the brake tester or pressure gauge after the hydraulic unit solenoid valve is operated.
2) VDC sequence control can be started by Subaru Select Monitor.
VDC SEQUENCE CONTROL WITH SUBARU SELECT MONITOR
NOTE: In the event of any trouble, sequence control will not operate.
1) Connect the Subaru Select Monitor to data link connector under the driver's side instrument panel lower cover.
2) Turn the ignition switch to ON.
3) Run the Subaru Select Monitor.
4) Set the Subaru Select Monitor to "Brake Control" mode.
5) When the "VDC Inspection Mode" is selected from the "Function check sequence" menu, the "VDC sequence control" will start.
6) "Select the [OK]" will be displayed. Select the [OK].
7) Operation points will be displayed on Subaru Select Monitor.
CONDITIONS FOR VDC SEQUENCE CONTROL
CONDITIONS FOR VDC SEQUENCE CONTROL (PART 1):
CONDITIONS FOR VDC SEQUENCE CONTROL (PART 2):
NOTE: The control operation starts from point A.
SPECIFICATION
CONDITIONS FOR COMPLETION OF VDC SEQUENCE CONTROL
When these conditions develop, the VDC sequence control stops and VDC operation is returned to the normal control mode.
1) When the speed of at least one wheel reaches 10 km/h (6 MPH).
2) When the brake pedal is pressed during sequence control and the stop light switch is set to ON.
3) After completion of VDC sequence control.
4) When a malfunction is detected.