Compressor HVAC: Testing and Inspection
CompressorINSPECTION
1. MAGNETIC CLUTCH CLEARANCE
1. Check the clearance of the entire circumference around the drive plate and pulley.
Standard: 0.45 ± 0.15 mm (0.0177 ± 0.0059 in)
2. MAGNETIC CLUTCH OPERATION
1. Disconnect the compressor connector.
2. Connect the battery positive (+) terminal to the terminal of compressor connector.
3. Make sure the magnet clutch engages.
If NG, replace the compressor.