Antitheft Relay: Testing and Inspection
INTERRUPT RELAYINSPECTION
Measure the interrupt relay resistance between terminals (indicated in the table) when connecting terminal No. 3 to battery positive terminal and terminal No. 1 to battery ground terminal.
If NG, replace the interrupt relay.
CAUTION: Do not connect the terminals to battery positive terminal and ground terminal incorrectly. If this happens, replace the interrupt relay.