P0244
DTC P0244 TURBO/SUPER CHARGER WASTEGATE SOLENOID "A" RANGE/PERFORMANCE1. OUTLINE OF DIAGNOSIS
Detect the malfunction of wastegate control solenoid valve function.
Judge NG when becoming high wastegate pressure.
2. COMPONENT DESCRIPTION
3. ENABLE CONDITION
Enable Conditions:
4. GENERAL DRIVING CYCLE
Always perform the diagnosis continuously.
5. DIAGNOSTIC METHOD
Abnormality Judgment
Judge as NG when the continuous time of meeting the malfunction criteria below becomes 1 second or more.
Time Needed for Diagnosis: 1 second
Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs.
Normality Judgment
Judge as OK and clear the NG when the malfunction criteria below are met.
6. DTC CLEAR CONDITION
- When the OK idling cycle is completed 40 times in a row
- When "Clear Memory" is performed
7. MALFUNCTION INDICATOR LIGHT CLEAR CONDITIONS
- When the OK driving cycle is completed 3 times in a row
- When "Clear Memory" is performed
8. FAIL SAFE
None
9. ECM OPERATION AT DTC SETTING
Memorize the freeze frame data. (For test mode $02)