Operation CHARM: Car repair manuals for everyone.

P2017

DTC P2017 INTAKE MANIFOLD RUNNER POSITION SENSOR / SWITCH CIRCUIT HIGH (BANK 1)

1. OUTLINE OF DIAGNOSIS
Detect open or short circuit of tumble generator valve position sensor.

Judge as NG if out of specification.

2. COMPONENT DESCRIPTION






3. ENABLE CONDITION

Enable Conditions:






4. GENERAL DRIVING CYCLE
Always perform the diagnosis continuously.

5. DIAGNOSTIC METHOD
Judge as NG if the duration of time while the following criteria are met is 0.5 seconds or more. Judge as OK and clear the NG when the malfunction criteria below are not met.






Time Needed for Diagnosis: 0.5 seconds

Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs.

6. DTC CLEAR CONDITION
- When the OK idling cycle is completed 40 times in a row
- When "Clear Memory" is performed

7. MALFUNCTION INDICATOR LIGHT CLEAR CONDITIONS
- When the OK driving cycle is completed 3 times in a row
- When "Clear Memory" is performed

8. FAIL SAFE

Tumble generator valve opening
- For tumble generator valve full closing points learning, not allowed to update to closing side.
- For tumble generator valve full opening points learning, not allowed to update to opening side.

9. ECM OPERATION AT DTC SETTING
Memorize the freeze frame data. (For test mode $02)