H4SO (2.5L SOHC)
DTC P0134 O2 SENSOR CIRCUIT NO ACTIVITY DETECTED (BANK 1 SENSOR 1)1. OUTLINE OF DIAGNOSIS
Detect open circuits of the sensor.
Judge as NG when the impedance of the element is large.
2. COMPONENT DESCRIPTION
3. ENABLE CONDITION
Enable Conditions:
4. GENERAL DRIVING CYCLE
Always perform the diagnosis continuously.
5. DIAGNOSTIC METHOD
Judge as NG when the continuous time of meeting the malfunction criteria below becomes more than 5 seconds.
Time Needed for Diagnosis: 5 seconds
Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs.
6. DTC CLEAR CONDITION
- When the OK idling cycle is completed 40 times in a row
- When "Clear Memory" is performed
7. MALFUNCTION INDICATOR LIGHT CLEAR CONDITION
- When the OK driving cycle is completed 3 times in a row
- When "Clear Memory" is performed
8. FAIL SAFE
- Front oxygen (A/F) sensor heater control: Not allowed to apply current to the heater.
- A/F main learning: Not allowed to calculate the A/F main learning compensation factor.
- A/F sub learning: Not allowed to calculate the A/F sub learning compensation factor.
- Purge control: Not allowed to purge.
9. ECM OPERATION AT DTC SETTING
Memorize the freeze frame data. (For test mode $02)