Blower Motor: Service and Repair
Blower Motor Unit AssemblyREMOVAL
1. Disconnect the ground cable from the battery.
2. Remove the glove box.
3. Loosen the nut to remove support beam stay.
4. Disconnect the connectors of the blower motor and intake actuator register.
5. Loosen the bolt and nut to remove blower motor unit assembly.
INSTALLATION
Install in the reverse order of removal.
HEATER COOLING UNIT
- Auto A/C model
Tightening torque: N.m (kgf.m, ft.lb)
T: 7.5 (0.76, 5.5)
- Manual A/C model
Tightening torque: N.m (kgf.m, ft.lb)
T: 7.5 (0.76, 5.5)