Condenser HVAC: Service and Repair
CondenserREMOVAL
1. Using the refrigerant recovery system, discharge refrigerant.
2. Disconnect the ground cable from the battery.
3. Disconnect the pressure hose and pipe from the condenser.
4. Remove the radiator bracket (A).
5. Remove two bolts. While lifting condenser, pull it out through space between the radiator and the radiator panel.
CAUTION:
- Be careful not to damage the radiator fins and condenser fins. If a damaged fin is found, repair it using a thin screwdriver.
- If the condenser is replaced, add appropriate amount of compressor oil to the compressor.
INSTALLATION
1. Install in the reverse order of removal.
CAUTION: Replace the O-rings on hoses or pipes with new parts, and then apply compressor oil. Confirm that lower guide of condenser fits into holes on radiator panel.
2. Charge refrigerant.
Tightening torque:
AIR CONDITIONING UNIT
Tightening torque: N.m (kgf.m, ft.lb)
T1: 7.4 (0.75, 5.4)
T2: 15 (1.5, 10.8)