DTC - General Description
DTC P2005 INTAKE MANIFOLD RUNNER CONTROL STUCK OPEN (BANK 2)1. OUTLINE OF DIAGNOSIS
Detect the malfunction of tumble generator valve motor function.
Judge open fixing malfunction when the opening degree is large even after finishing the tumble generator valve closing driving.
3. ENABLE CONDITION
3. GENERAL DRIVING CYCLE
Always perform the diagnosis continuously.
4. DIAGNOSTIC METHOD
- Abnormality Judgment
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
Time Needed for Diagnosis: 3000 ms
Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs.
- Normality Judgment
Judge as OK and clear the NG if the continuous time while the following conditions are established is more than the predetermined time.
Time Needed for Diagnosis: Less than 1 second
5. DTC CLEAR CONDITION
- When the OK idling cycle is completed 40 times in a row
- When "Clear Memory" is performed
6. MALFUNCTION INDICATOR LIGHT CLEAR CONDITIONS
- When the OK driving cycle is completed 3 times in a row
- When "Clear Memory" is performed
7. FAIL SAFE
Tumble generator valve opening
- For tumble generator valve full closing points learning, not allowed to update to closing side.
- For tumble generator valve full opening points learning, not allowed to update to opening side.
Tumble generator valve control
- Output the open signal.
8. ECM OPERATION AT DTC SETTING
Memorize the freeze frame data. (For test mode $02)