DTC - General Description
DTC P2440 SECONDARY AIR INJECTION SYSTEM SWITCHING VALVE STUCK OPEN (BANK 1)1. OUTLINE OF DIAGNOSIS
Detect NG judging from secondary air delivery pipe pressure, pulse of secondary air delivery pipe pressure and secondary air pipe airflow amount.
2. ENABLE CONDITION
3. GENERAL DRIVING CYCLE
Perform diagnosis during secondary air pump operation
4. DIAGNOSTIC METHOD
Measure secondary air delivery pipe pressure, pulse of secondary air delivery pipe pressure and secondary air pipe airflow amount.
Pump supply pressure check
Perform the system function diagnosis with how much the pressure rises when the secondary air pump is turned from OFF to ON.
Judge as NG if delivery pipe pressure does not rise though it should when the secondary air pump turns OFF -> ON.
- Abnormality Judgment
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
Time Needed for Diagnosis: 1984 ms + 2816 ms
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.
- Normality Judgment
Judge as OK and clear the NG if the continuous time while the following conditions are established is more than the predetermined time.
Time Needed for Diagnosis: 1984 ms + 2816 ms
Combination valve both closed pulse diagnosis
Perform open stuck diagnosis of both combination valves using delivery pipe pressure pulse when both combination valves are closed.
Determine which side of valves is stuck open by comparing secondary air flow amount when RH combination valve is closed with that when LH combination valve is closed. Calculate voltage pulse of the pump supply pipe pressure when both combination valves are closed. The calculation should be small because there is no pulse from supply pipe pressure with both combination valves closed. When the calculation is large, determine that either of the combination valves is stuck open.
Determine which side of valves is stuck open by comparing secondary air flow amount when the RH combination valve is closed with that when the LH combination valve is closed. Air flow amount is larger on the open stuck valve.
- Abnormality Judgment
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
Time Needed for Diagnosis: 4000 ms + 992 ms + 992 ms + 992 ms
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.
- Normality Judgment
Judge as OK and clear the NG if the continuous time while the following conditions are established is more than the predetermined time.
Time Needed for Diagnosis: 4000 ms + 992 ms + 992 ms + 992 ms
Combination valve changeover pressure diagnosis
Perform the RH combination valve stuck closed diagnosis with the variation of delivery pipe pressure when the RH combination valve turns closed -> open.
Delivery pipe pressure should vary when the RH combination valve turns closed -> open.
When the variation is small, determine that the RH combination valve is stuck closed.
- Abnormality Judgment
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
Time Needed for Diagnosis: 4000 ms + 992 ms + 992 ms + 992 ms
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.
- Normality Judgment
Judge as OK and clear the NG if the continuous time while the following conditions are established is more than the predetermined time.
Time Needed for Diagnosis: 4000 ms + 992 ms + 992 ms + 992 ms
Perform the LH combination valve stuck closed diagnosis with the variation of delivery pipe pressure when the LH combination valve turns open -> closed.
Delivery pipe pressure should vary when the LH combination valve turns open -> closed.
When the variation is small, determine that the LH combination valve is stuck closed.
- Abnormality Judgment
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
Time Needed for Diagnosis: 4000 ms + 992 ms + 992 ms + 992 ms
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.
- Normality Judgment
Judge as OK and clear the NG if the continuous time while the following conditions are established is more than the predetermined time.
Time Needed for Diagnosis: 4000 ms + 992 ms + 992 ms + 992 ms
Overflow diagnosis
Perform secondary air system flow abnormality diagnosis using both sides of combination valves secondary air amount when both are closed. Judge as secondary air system flow abnormality either if there is excessive secondary air flow amount with the RH combination valve closed, or if there is excessive secondary air flow amount with the LH combination valve closed.
- Abnormality Judgment
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
PORL: Both banks all closed pressure
POR: Right bank all closed pressure
POL: Left bank all closed pressure
Time Needed for Diagnosis: 4000 ms + 992 ms + 992 ms + 992 ms
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.
- Normality Judgment
Judge as OK and clear the NG if the continuous time while the following conditions are established is more than the predetermined time.
PORL: Both banks all closed pressure
POR: Right bank all closed pressure
POL: Left bank all closed pressure
Time Needed for Diagnosis: 4000 ms + 992 ms + 992 ms + 992 ms
5. DTC CLEAR CONDITION
- When the OK idling cycle is completed 40 times in a row
- When "Clear Memory" is performed
6. MALFUNCTION INDICATOR LIGHT CLEAR CONDITIONS
- When the OK driving cycle is completed 3 times in a row
- When "Clear Memory" is performed
7. FAIL SAFE
None
8. ECM OPERATION AT DTC SETTING
- Memorize the freeze frame data. (For test mode $02)
- Memorize the diagnostic value and trouble standard value. (For test mode $06)