Variable Valve Timing Pressure Switch: Service and Repair
Variable Valve Lift Diagnosis Oil Pressure SwitchREMOVAL
1. Remove the collector cover.
2. Disconnect the ground cable from the battery.
3. Remove the air intake chamber.
4. Disconnect the connector from the variable valve lift diagnosis oil pressure switch.
5. Remove the variable valve lift diagnosis oil pressure switch.
INSTALLATION
Install in the reverse order of removal.
NOTE: Apply liquid gasket to the variable valve lift diagnosis oil pressure switch threads.
Liquid gasket: THREE BOND 1324 (Part No. 004403042) or equivalent
Tightening torque: 17 N.m (1.7 kgf.m, 12.5 ft.lb)