HVAC System
Refrigerant Pressure with Manifold Gauge SetPROCEDURE
1. Place the vehicle in the shade and windless condition.
2. Connect the manifold gauge set.
3. Open the front windows and close all doors.
4. Open the front hood.
5. Increase the engine to 1,500 rpm.
6. Turn on the A/C switch.
7. Turn the temperature control switch to MAX COOL.
8. Put in RECIRC position.
9. Turn the blower control switch to HI.
10. Read the gauge.
Standard:
Low: 127 - 196 kPa (1.3 - 2.0 kg/sq.cm, 18 - 28 psi)
High: 1,471 - 1,667 kPa (15 - 17 kg/sq.cm, 213 - 242 psi)
Ambient temperature: 30 - 35 °C (86 - 95 °F)