Keyless Entry Transmitter: Testing and Inspection
TransmitterREPLACEMENT
1. REGISTRATION OF KEYLESS TRANSMITTER WITH SUBARU SELECT MONITOR
NOTE:
- A maximum of four keyless transmitter can be registered for each individual vehicle.
- When replacing or adding the keyless transmitter, new registration of transmitter is necessary.
1. Prepare the Subaru Select Monitor III kit.
2. Prepare PC with Subaru Select Monitor III installed.
3. Connect USB cable to SDI (Subaru Diagnostic Interface) and PC USB port (Subaru Select Monitor III dedicated port).
NOTE: Subaru Select Monitor III dedicated port indicates USB port used when Subaru Select Monitor III is installed.
4. Connect the diagnosis cable to SDI.
5. Connect SDI to data link connector located in the lower portion of the instrument panel (on the driver's side).
CAUTION: Do not connect scan tools other than the Subaru Select Monitor.
6. Start the PC.
7. Turn the ignition switch to ON (engine OFF), and run the "PC application for Subaru Select Monitor III".
8. On the <
9. Input the 8-digit ID number attached to the tag plate of the transmitter or inside the transmitter, from left to right. Press the [Enter] key.
NOTE: Press the [/\] key on the Subaru Select Monitor to increase the number, and the [\/] key to decrease. Press the [<] key to move to the digit in the left, and [>] to the right.
10. The ID number you have entered will be shown. Make sure that the ID number shown is the same as that of the tag plate.
11. Press the [OK] key if the ID number is correct. Press the [NO] key if incorrect, to return to the step 3) and try again.
12. <
13. <
14. To exit, select <
NOTE:
- If the registration fails, <
- <