Main Relay (Computer/Fuel System): Testing and Inspection
Main RelayINSPECTION
1. Measure the resistance between main relay terminals.
2. Connect terminal No. 3 to the battery positive terminal and the No. 4 terminal to the battery ground terminal, and measure the resistance between the main relay terminals.