Variable Induction Control Valve: Service and Repair
Tumble Generator Valve AssemblyREMOVAL
1. Release the fuel pressure.
2. Remove the collector cover.
3. Disconnect the ground cable from battery.
4. Open the fuel filler flap lid, and remove the fuel filler cap.
5. Remove the intake manifold.
6. Disconnect the connector from the tumble generator valve assembly.
7. Remove the fuel injector.
8. Remove the tumble generator valve body from intake manifold.
INSTALLATION
Install in the reverse order of removal.
NOTE: Use a new gasket.