Condenser HVAC: Service and Repair
CondenserREMOVAL
1. Using the refrigerant recovery system, drain the refrigerant.
2. Disconnect the ground cable from the battery.
3. Disconnect the pressure hose and pipe from the condenser.
4. Remove the radiator bracket (A) and hood stay (B).
5. Remove the front grille.
6. Remove two bolts. While lifting the condenser, pull out through space between the radiator and the radiator panel.
CAUTION:
- Be careful not to damage the condenser fins. If a damaged fin is found, repair it using a thin screwdriver.
- When replacing the condenser, add an appropriate amount of compressor oil to the compressor.
INSTALLATION
1. Install in the reverse order of removal.
CAUTION: Replace the O-rings on hoses or pipes with new parts, and then apply compressor oil. Confirm that lower guide (A) of condenser fits into holes on radiator panel.
2. Charge with refrigerant.
AIR CONDITIONING UNIT
Tightening torque: N.m (kgf.m, ft.lb)
T1: 7.5 (0.76, 5.5)
T2: 10 (1.0, 7.4)
T3: 5 (0.5, 3.7)