Operation CHARM: Car repair manuals for everyone.

Room Light

Room Light

INSPECTION

1. ROOM LIGHT BULB
1. Visually check the bulb for blow out.
2. Check the bulb specification. Specifications
3. If NG, replace the bulb with a new part.

2. ROOM LIGHT SWITCH
Measure the resistance between room light switch terminals.






Connect terminal No. 3 to the battery positive terminal and terminal No. 1 and No. 2 to the battery ground terminal, and check room light operation.