Wheels: Testing and Inspection
Wheel BalancingADJUSTMENT
NOTE: Because an adhesive type weight is adopted for the outside balance weight of 17-inch and 18inch wheels, change the setting of the wheel balancer to adhesive type weight.
1. Remove the balance weights.
CAUTION:
- Be careful not to damage the wheel.
- Completely remove the double-sided tape of the adhesive weight from the wheel.
2. Using the wheel balancer, measure wheel balance.
3. Select a weight close to the value measured by wheel balancer.
CAUTION: Use SUBARU genuine balance weights.
4. Install the selected weight to the point designated by the wheel balancer.
CAUTION:
- Degrease the wheel surface where the adhesive type weight will be applied.
- Press the adhesive type weight by 25 N (2.5 kgf, 5.6 lb or more per 5 g (0.18 oz) for 2 seconds or more and attain full adhesion.
- Total application of the adhesive type weight should be 100 g (3.53 oz) or less.
- The total weight of all adhesive weight on models with transmitters (tire pressure sensor is to be 120 g (4.23 oz. or less)
5. Using the wheel balancer, measure the wheel balance again. Check that wheel balance is correctly adjusted.
NOTE: Knock-on type balance weights for aluminum wheels can be used on any 15 to 18 inch aluminum wheels.
Service limit A:
Knock-on type weight for steel wheel.
5 - 25 g (0.18 - 0.88 oz.2.0 mm (0.08 in)
30 g (1. 06 oz. or more 1.8 mm (0.07 in)
Knock-on type weight for aluminum wheel.
5 - 25 g (0.18 - 0.88 oz.5. 0 mm (0.20 in)
30 g (1. 06 oz. or more 4.5 mm (0.177 in)